Sacrificial anode cathodic protection (SACP)
Design, supply, installation, testing and commissioning of galvanic anode systems. Includes Temporary Cathodic Protection (TCP) for pipelines during construction.
What we deliver
Design
Anode material, size, number and spacing worked out from soil resistivity and current demand, with design life calculations.
Supply
Magnesium, zinc and aluminium anodes, magnesium and zinc ribbon anodes, test stations and cables.
Installation
Anodes installed in backfill and connected through test stations, so each anode’s output can be measured.
Testing & commissioning
Structure-to-soil potentials and anode currents measured at each test station and recorded in the commissioning report.
Temporary cathodic protection during construction
A newly laid pipeline can start to corrode before its permanent CP system is energised. Temporary CP protects it through construction, with sacrificial anodes connected at test stations as each section is laid.
- TCP design for the construction period, section by section
- Magnesium anodes or zinc ribbon, installed as the pipeline is laid and backfilled
- Potential monitoring through construction, until the permanent system takes over
- Disconnection or isolation of TCP anodes at handover, as the specification requires
How a sacrificial anode system works
The anode is a more active metal than steel. Connected to the structure, it corrodes in its place and supplies protective current without any power source.
Sacrificial anode (SACP)
A more active metal corrodes in place of the steel. No power supply needed.
SACP or ICCP?
Sacrificial systems suit well-coated or shorter structures, temporary protection and sites without power.
| Attribute | Sacrificial anode (SACP) | Impressed current (ICCP) |
|---|---|---|
| Current source | The anode metal itself, which is more active than steel | Transformer rectifier unit, CPPSM or switch mode power supply |
| Anodes | Magnesium, zinc and aluminium; magnesium and zinc ribbon | MMO tubular, linear and wire anodes; high silicon chromium iron, in carbonaceous backfill |
| Suited to | Well-coated or shorter pipelines, plant piping, temporary CP during construction, sites without power | Long cross-country pipelines, tank farms, and large structures with high current demand |
| Output | Fixed by anode size and soil resistivity | Adjustable, with manual or automatic control |
| Upkeep | No power supply; anodes are consumed and replaced at end of life | Needs a power supply and routine checks of rectifier output |
How protection is verified
Structure potentials are measured against a reference electrode, typically copper/copper sulphate (CSE). A common criterion is a polarized, instant-off potential of −850 mV CSE or more negative, or at least 100 mV of cathodic polarization, as the project specification requires. We work to the client’s specification and the standards it calls up, such as NACE SP0169, ISO 15589-1 and PNGRB regulations.