Sacrificial anode cathodic protection (SACP)

Design, supply, installation, testing and commissioning of galvanic anode systems. Includes Temporary Cathodic Protection (TCP) for pipelines during construction.

What we deliver

  • Design

    Anode material, size, number and spacing worked out from soil resistivity and current demand, with design life calculations.

  • Supply

    Magnesium, zinc and aluminium anodes, magnesium and zinc ribbon anodes, test stations and cables.

  • Installation

    Anodes installed in backfill and connected through test stations, so each anode’s output can be measured.

  • Testing & commissioning

    Structure-to-soil potentials and anode currents measured at each test station and recorded in the commissioning report.

Temporary cathodic protection during construction

A newly laid pipeline can start to corrode before its permanent CP system is energised. Temporary CP protects it through construction, with sacrificial anodes connected at test stations as each section is laid.

  • TCP design for the construction period, section by section
  • Magnesium anodes or zinc ribbon, installed as the pipeline is laid and backfilled
  • Potential monitoring through construction, until the permanent system takes over
  • Disconnection or isolation of TCP anodes at handover, as the specification requires

How a sacrificial anode system works

The anode is a more active metal than steel. Connected to the structure, it corrodes in its place and supplies protective current without any power source.

Sacrificial anode system: a buried magnesium or zinc anode is cabled to the pipeline through a test station, and protective current flows from the anode through the soil onto the pipe. Test station Mg / Zn anode Protective current Pipeline (cathode)

Sacrificial anode (SACP)

A more active metal corrodes in place of the steel. No power supply needed.

SACP or ICCP?

Sacrificial systems suit well-coated or shorter structures, temporary protection and sites without power.

Sacrificial and impressed current systems compared
AttributeSacrificial anode (SACP)Impressed current (ICCP)
Current sourceThe anode metal itself, which is more active than steelTransformer rectifier unit, CPPSM or switch mode power supply
AnodesMagnesium, zinc and aluminium; magnesium and zinc ribbonMMO tubular, linear and wire anodes; high silicon chromium iron, in carbonaceous backfill
Suited toWell-coated or shorter pipelines, plant piping, temporary CP during construction, sites without powerLong cross-country pipelines, tank farms, and large structures with high current demand
OutputFixed by anode size and soil resistivityAdjustable, with manual or automatic control
UpkeepNo power supply; anodes are consumed and replaced at end of lifeNeeds a power supply and routine checks of rectifier output

How protection is verified

Structure potentials are measured against a reference electrode, typically copper/copper sulphate (CSE). A common criterion is a polarized, instant-off potential of −850 mV CSE or more negative, or at least 100 mV of cathodic polarization, as the project specification requires. We work to the client’s specification and the standards it calls up, such as NACE SP0169, ISO 15589-1 and PNGRB regulations.