Impressed current cathodic protection (ICCP)

Design, supply, installation, testing and commissioning of ICCP systems for pipelines, buried piping and tank bottoms.

What we deliver

  • Design

    Current requirement calculations, anode bed design, TR unit sizing, cable schedules, drawings and design reports, based on survey data and the project specification.

  • Supply

    TR units, CPPSM and SMPS units, MMO and high silicon chromium iron anodes, coke breeze backfill, junction boxes, test stations and cables. Test stations, AJB and CJB are made in our workshop.

  • Installation

    Anode beds, TR units, junction boxes, test stations and cable networks, with cable-to-pipe connections by thermit welding or pin brazing.

  • Testing & commissioning

    Native potential survey, energisation, current adjustment, on/off potential measurements and interference checks, recorded in a commissioning report.

How an ICCP system works

A transformer rectifier drives direct current from long-life anodes through the soil onto the structure. Output can be adjusted as the coating ages or the current demand changes.

Impressed current system: a transformer rectifier converts AC to DC, its positive output feeds an anode bed in coke backfill, its negative output is bonded to the pipeline, and current flows from the anode bed through the soil onto the pipe. AC supply TR unit AC in, DC out − + Anode bed MMO / HSCI in coke backfill Pipeline (cathode)

Impressed current (ICCP)

A DC power source drives current from long-life anodes. Output is adjustable.

Where we use ICCP

  • Cross-country pipelines

    Long pipelines with high current demand, where adjustable output covers the changing coating condition along the route.

  • Buried plant & firewater piping

    Congested plant networks, with anode beds sited to spread current and limit interference with other buried structures.

  • Storage tank bottoms

    External protection of aboveground storage tank bottom plates, with anode grids beneath new tanks or anode beds around existing ones.

ICCP or SACP?

The right system depends on current demand, soil resistivity, power availability and design life.

Sacrificial and impressed current systems compared
AttributeSacrificial anode (SACP)Impressed current (ICCP)
Current sourceThe anode metal itself, which is more active than steelTransformer rectifier unit, CPPSM or switch mode power supply
AnodesMagnesium, zinc and aluminium; magnesium and zinc ribbonMMO tubular, linear and wire anodes; high silicon chromium iron, in carbonaceous backfill
Suited toWell-coated or shorter pipelines, plant piping, temporary CP during construction, sites without powerLong cross-country pipelines, tank farms, and large structures with high current demand
OutputFixed by anode size and soil resistivityAdjustable, with manual or automatic control
UpkeepNo power supply; anodes are consumed and replaced at end of lifeNeeds a power supply and routine checks of rectifier output

How protection is verified

Structure potentials are measured against a reference electrode, typically copper/copper sulphate (CSE). A common criterion is a polarized, instant-off potential of −850 mV CSE or more negative, or at least 100 mV of cathodic polarization, as the project specification requires. We work to the client’s specification and the standards it calls up, such as NACE SP0169, ISO 15589-1 and PNGRB regulations.