AC/DC interference modelling & mitigation

Field measurements and software modelling to assess interference, followed by mitigation design, installation and verification.

Where interference comes from

  • AC interference

    High-voltage power lines and AC-electrified railways that share a corridor with a pipeline induce AC voltage on it. The result can be AC corrosion at coating defects and unsafe touch voltages.

  • DC interference

    DC traction systems, other operators’ CP systems and industrial DC sources drive stray current through the soil. Where that current leaves the pipeline, the steel corrodes.

Our approach

  1. Field measurements

    AC pipe-to-soil voltage, AC current density on 1 cm² and 10 cm² coupons made in our workshop, DC potential fluctuations logged with data loggers, and soil resistivity along the corridor.

  2. Software modelling

    The pipeline, power lines and soil are modelled to predict induced voltage and current density, including fault conditions, and to test mitigation options before anything is built.

  3. Mitigation design

    Gradient control wires, zinc ribbon, earthing systems with solid state decouplers, polarization cells, surge diverters and drainage bonds, sized for the predicted conditions.

  4. Installation

    Our site teams install the mitigation system and its test points.

  5. Verification

    Post-installation measurements confirm that voltages and current densities are within the criteria the specification calls up, such as ISO 18086 and NACE SP0177.